PART 3-EXECUTION
3.1 SURFACE CONDITIONS
-
Examine the areas and conditions under which work of
this section will be
performed . Correct conditions detrimental to timely and
proper completion
of the work.
Do not proceed until unsatisfactory conditions are
corrected.
3.2 INSTALLATION
-
Placing frames:
-
Install frames in accordance with manufacturer's
instructions. Rough
opening to be framed out using steel studs, turned so
that open end faces
opening.
-
Coordinate with all wall construction for anchor
placement.
-
Field cut jamb legs if required to fit actual finished
opening dimension.
-
Install plumb and true to lines, with all necessary
clips, anchors, and
fastenings.
Brace until adjacent walls and finishes are constructed
and securely
anchored.
-
Coordinate installation of glass and glazing to comply
with Section 08800
.Glazing. for glazed lights.
-
Accurately join, fit and reinforce corners to flush
hairline joints.
-
TOLERANCES
-
Install frames to permit hanging wood doors to AWI requirements as specified
in Section 08211.
- ADJUSTING AND CLEANING
1.
Adjust hardware for smooth and balanced door movement.
2.
Clean completed systems promptly after erection taking
care to avoid
damage to finishes.
3.3 ADJUST AND CLEAN
A. FINAL ADJUSTMENTS:
-
Check and re-adjust operating finish hardware items in
hollow metal
work just prior to final inspection.
-
Leave work in complete and proper operating condition.
-
Remove defective work and replace with work complying
with the
specified requirements.
-
Touch-up as needed so that touch-up is not visible from
a distance of 4
feet. Remove
& replace frames which can not be satisfactorily
adjusted.
<<Previous Page |